Description
SKF LAGD 125/WM2 Automatic Lubricator with LGWM 2 Grease
The SKF LAGD 125/WM2 is a gas-driven, single-point automatic lubricator pre-filled with 125 mL of SKF LGWM 2 grease. It provides an adjustable dispensing period for suitable bearing and auxiliary-equipment lubrication points where the lubricant, required feed rate and installation conditions have been confirmed.
Technical specifications
| Manufacturer | SKF |
|---|---|
| Order designation | LAGD 125/WM2 |
| Lubricant | SKF LGWM 2 grease, pre-filled |
| Lubricant volume | 125 mL |
| Operating principle | Gas cell producing inert gas for single-point dispensing |
| Dispensing-period setting | 1–12 months, subject to temperature and application |
| High-temperature setting limitation | For constant ambient temperatures of +40 to +60 °C, the manufacturer recommends a maximum setting of 6 months |
| Operating ambient temperature | −20 to +60 °C |
| Maximum pressure | 5 bar at start-up |
| Connection thread | R 1/4 |
| Maximum grease feed-line length | 300 mm |
| Protection | IP68, subject to correct installation |
| Approximate weight with lubricant | 200 g |
Application and selection
For suitable wind farm auxiliary machinery and accessible bearing points, an individually selected automatic lubricator can support a planned relubrication schedule. The required grease quantity, operating duty, lubricant compatibility and inspection interval determine whether this unit is suitable.
Check the equipment manufacturer's grease specification and the compatibility of any existing lubricant before selection. Backpressure, ambient temperature and feed-line arrangement affect dispensing. The grease's own temperature capability does not extend the lubricator's −20 to +60 °C operating limit. Large-volume or centralised wind turbine lubrication duties require a separately engineered system.
Information for your quotation
- Required quantity and equipment or bearing lubrication point
- OEM lubricant specification, existing grease and required replenishment rate
- Operating temperature, feed-line length, connection and expected backpressure
- Accessory requirements, acceptable remaining shelf life and delivery postcode
The product image shows the LAGD 125/WM2 lubricator. Adapters, extension lines and installation accessories are separately specified.
Supply availability, included items, price, freight, lead time and warranty arrangements are confirmed in the written quotation for the selected configuration.