Beckhoff EL3356-0010 EtherCAT Bridge Measurement Terminal
The Beckhoff EL3356-0010 connects a full-bridge strain-gauge transducer or load cell to an EtherCAT system. Its configurable conversion rate and distributed-clock support make it an option for instrumented load, torque and test-bench measurements in a wind energy engineering project.
Technical specifications
| Manufacturer | Beckhoff |
|---|---|
| Model | EL3356-0010 |
| Measurement channel | One full resistor bridge; two inputs for bridge and reference voltages |
| Transducer wiring | 4-wire or 6-wire |
| Bridge voltage input UD | Maximum ±27 mV |
| Reference voltage input UREF | Maximum ±13.8 V |
| Recommended nominal sensitivity | 0.5–4 mV/V |
| Conversion rate | 4–10,000 samples/s, configuration dependent |
| Conversion time | 0.1–250 ms |
| Resolution | 24 bit; 32-bit process-value representation |
| Synchronisation | EtherCAT distributed clocks |
| Bridge excitation | External source, up to 12 V DC through power contacts, matched to the sensor |
| E-bus current | Typically 280 mA |
| Operating temperature | −25 to +55°C |
| Protection and mounting | IP20; 35 mm DIN rail inside a suitable enclosure |
| Dimensions | 12 × 100 × 68 mm |
| Weight | Approximately 60 g |
Application and selection
The complete acquisition chain requires a compatible bridge transducer, suitable excitation, EtherCAT coupler or controller, wiring, software configuration and calibration. This terminal provides the electrical acquisition interface; the transducer and the mechanical installation determine the measured load or torque.
Choose the conversion time and filters for the signal bandwidth and required noise performance. The 10,000 samples/s limit and the finest filtered measurement performance apply to different operating settings. Confirm the complete EL3356-0010 model when specifying replacements or expanding an existing rack.
Information for your quotation
- Sensor model, bridge resistance, sensitivity and excitation requirement
- Measurement range, bandwidth and required sampling rate
- Existing EtherCAT controller, coupler and available E-bus capacity
- Quantity, calibration requirements and delivery postcode
The second image is the manufacturer's terminal and bridge-connection illustration. Installation should follow the documentation for the ordered revision.
Supply availability, included items, price, freight, lead time and warranty arrangements are confirmed in the written quotation for the selected configuration.