Beckhoff EL3356-0010 EtherCAT Bridge Measurement Terminal

(No reviews yet) Write a Review
SKU:
MTR-WE-099
MPN:
EL3356-0010
  • Beckhoff EL3356-0010 bridge measurement terminal product view
  • Beckhoff EL3356-0010 manufacturer terminal and bridge connection illustration
Request a Project Quote

Description

Beckhoff EL3356-0010 EtherCAT Bridge Measurement Terminal

The Beckhoff EL3356-0010 connects a full-bridge strain-gauge transducer or load cell to an EtherCAT system. Its configurable conversion rate and distributed-clock support make it an option for instrumented load, torque and test-bench measurements in a wind energy engineering project.

Request a Project Quote

Technical specifications

ManufacturerBeckhoff
ModelEL3356-0010
Measurement channelOne full resistor bridge; two inputs for bridge and reference voltages
Transducer wiring4-wire or 6-wire
Bridge voltage input UDMaximum ±27 mV
Reference voltage input UREFMaximum ±13.8 V
Recommended nominal sensitivity0.5–4 mV/V
Conversion rate4–10,000 samples/s, configuration dependent
Conversion time0.1–250 ms
Resolution24 bit; 32-bit process-value representation
SynchronisationEtherCAT distributed clocks
Bridge excitationExternal source, up to 12 V DC through power contacts, matched to the sensor
E-bus currentTypically 280 mA
Operating temperature−25 to +55°C
Protection and mountingIP20; 35 mm DIN rail inside a suitable enclosure
Dimensions12 × 100 × 68 mm
WeightApproximately 60 g

Application and selection

The complete acquisition chain requires a compatible bridge transducer, suitable excitation, EtherCAT coupler or controller, wiring, software configuration and calibration. This terminal provides the electrical acquisition interface; the transducer and the mechanical installation determine the measured load or torque.

Choose the conversion time and filters for the signal bandwidth and required noise performance. The 10,000 samples/s limit and the finest filtered measurement performance apply to different operating settings. Confirm the complete EL3356-0010 model when specifying replacements or expanding an existing rack.

Information for your quotation

  • Sensor model, bridge resistance, sensitivity and excitation requirement
  • Measurement range, bandwidth and required sampling rate
  • Existing EtherCAT controller, coupler and available E-bus capacity
  • Quantity, calibration requirements and delivery postcode

The second image is the manufacturer's terminal and bridge-connection illustration. Installation should follow the documentation for the ordered revision.

Supply availability, included items, price, freight, lead time and warranty arrangements are confirmed in the written quotation for the selected configuration.